FOI release

Air quality monitoring

Case reference FOI2026/01404

Received 25 August 2026

Published 10 September 2026

Request

1. Does the authority operate its own air quality monitoring stations or sensors, independent of Defra's national networks? 2. How many air quality monitoring stations or sensors are currently in operation across the authority's area? 3. What type of monitoring equipment is used (manufacturer, model, and parameters measured, for example PM2.5, PM10, NO2, or O3)? 4. Where is each monitoring unit located (addresses or geographic coordinates)? 5. Who operates the monitoring system (an in-house team or an external provider)? 6. What system is used to present and publish the monitoring data (web platform, mobile application, or public information display)? Please provide the URL if the data is published online. II. Ownership and contracts 7. Is the monitoring equipment owned by the authority? If so, please state: * the date of acquisition, * the cost of acquisition, * who services the equipment and under what agreement (provider name, type of contract, and contract term). 8. If the equipment is not owned by the authority, under what arrangement is it used (rental, lease, hire, loan, or other)? Please state: * the start date of the current agreement, * the end date of the agreement, * the name of the provider. III. Costs 9. What was the total cost of purchasing and commissioning the current monitoring system? 10. What is the annual cost of running the system, including servicing, calibration, data transmission, and hosting of the presentation platform? 11. What budget has been allocated to air quality monitoring for the 2026/27 financial year? IV. Development plans 12. Are any modifications to, or expansion of, the current monitoring system planned? If so, please state: * what changes are planned (for example additional sensors, a change of technology, or expansion of the data platform), * the intended timescale, * the estimated budget. 13. If the authority does not currently operate an air quality monitoring system, does it plan to implement one? If so, please state the intended timescale and the budget envisaged. V. External funding 14. Does the authority plan to apply for any grants or external funding related to air quality monitoring? 15. Which funding programmes are being considered or have already been identified (for example Defra's Air Quality Grant, or other national, devolved, or regional schemes)? 16. Has the authority previously drawn on external funding for this purpose? If so, from which sources and in what amounts? VI. Collaboration and data integration 17. Does the authority collaborate on air quality monitoring with any other organisations (for example universities, non-governmental organisations, Defra, or neighbouring authorities)? 18. Is the data from the authority's monitoring system integrated with any publicly accessible air quality platforms (for example UK-AIR)? 19. Does the authority use air quality monitoring data to inform operational decisions (for example issuing air quality alerts, managing traffic, or Local Air Quality Management action planning under Part IV of the Environment Act 1995)? 20. Does the authority use air quality monitoring data to inform or educate residents? VII. Air quality in planning and environmental permitting 21. When determining major development proposals (for example large construction, infrastructure, industrial, or minerals and waste schemes), does the authority require air quality or dust assessment, and does it attach conditions requiring air quality monitoring, dust management, or a Construction Environmental Management Plan during the works? 22. For industrial installations that the authority regulates through environmental permitting, does it set air emission limits or air quality monitoring requirements as permit conditions? 23. Where such conditions or permit requirements are imposed, is the operator required to carry out the monitoring, and is the resulting data reported to the authority or made publicly available?

Response

1.  Does the authority operate its own air quality monitoring stations or sensors, independent of Defra's national networks?

Yes
  2.  How many air quality monitoring stations or sensors are currently in operation across the authority's area?

One
  3.  What type of monitoring equipment is used (manufacturer, model, and parameters measured, for example PM2.5, PM10, NO2, or O3)?

API M200E NOx

 

TEOM - PM10

 

Thermo Scientific 1405F PM2.5 Analyser (BAM)
  4.  Where is each monitoring unit located (addresses or geographic coordinates)?

A26 St Johns Road Southborough (558260, 141599)
  5.  Who operates the monitoring system (an in-house team or an external provider)?

Calibrations and routine maintenance done in house, servicing and breakdowns covered by specialist engineers.
  6.  What system is used to present and publish the monitoring data (web platform, mobile application, or public information display)? Please provide the URL if the data is published online.
www.kentair.org.uk
II. Ownership and contracts

7.               Is the monitoring equipment owned by the authority? If so, please state:
Yes

     the date of acquisition,
Information not held for most of the equipment as it has been in place for many years. BAM added second hand in 2022
 
   the cost of acquisition,
BAM added second hand in 2022 at a cost of £9,000 supplied and installed. Information not held for the other equipment.
     who services the equipment and under what agreement (provider name, type of contract, and contract term). Serviced by Matts Monitors - contract is 5+1+1 years.

8.               If the equipment is not owned by the authority, under what arrangement is it used (rental, lease, hire, loan, or other)? Please state:
N/A

 
   the start date of the current agreement,
     the end date of the agreement,
 
   the name of the provider.

III. Costs

9.               What was the total cost of purchasing and commissioning the current monitoring system? Information not held

10.            What is the annual cost of running the system, including servicing, calibration, data transmission, and hosting of the presentation platform?

Information not held. It is not possible to break down costs in this way.

11.            What budget has been allocated to air quality monitoring for the 2026/27 financial year?
There is no separate budget for air quality monitoring.


IV. Development plans

12.            Are any modifications to, or expansion of, the current monitoring system planned? If so, please state:
No

     what changes are planned (for example additional sensors, a change of technology, or expansion of the data platform),
 
   the intended timescale,
  *   the estimated budget.

13.            If the authority does not currently operate an air quality monitoring system, does it plan to implement one? If so, please state the intended timescale and the budget envisaged.
N/A

V. External funding

14.            Does the authority plan to apply for any grants or external funding related to air quality monitoring?
No

15.            Which funding programmes are being considered or have already been identified (for example Defra's Air Quality Grant, or other national, devolved, or regional schemes)?
None

16.            Has the authority previously drawn on external funding for this purpose? If so, from which sources and in what amounts?
BAM was purchased with S106 funding

VI. Collaboration and data integration

17.            Does the authority collaborate on air quality monitoring with any other organisations (for example universities, non-governmental organisations, Defra, or neighbouring authorities)?
Yes

18.            Is the data from the authority's monitoring system integrated with any publicly accessible air quality platforms (for example UK-AIR)?
Yes

19.            Does the authority use air quality monitoring data to inform operational decisions (for example issuing air quality alerts, managing traffic, or Local Air Quality Management action planning under Part IV of the Environment Act 1995)?
Yes

20.            Does the authority use air quality monitoring data to inform or educate residents?
Yes

VII. Air quality in planning and environmental permitting

21.            When determining major development proposals (for example large construction, infrastructure, industrial, or minerals and waste schemes), does the authority require air quality or dust assessment, and does it attach conditions requiring air quality monitoring, dust management, or a Construction Environmental Management Plan during the works?
Yes

22.            For industrial installations that the authority regulates through environmental permitting, does it set air emission limits or air quality monitoring requirements as permit conditions?
No

23.            Where such conditions or permit requirements are imposed, is the operator required to carry out the monitoring, and is the resulting data reported to the authority or made publicly available?
No

Documents

There are no documents for this release.

This is Tunbridge Wells Borough Council's response to a freedom of information (FOI) or environmental information regulations (EIR) request.